<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-08 13-09-33
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 69 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 3.0 kHz -20 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19080 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,9 dBr 2,63 dBr 3,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sinfonia B-duuri: II. Andante (Schmitt Joseph) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/04/08 13.08.30 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,9 dBr MIN: 0,9 dBr AVE: 2,63 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2025/04/08 13.08.29) 12.54 12.56 12.58 13.00 13.02 13.04 13.06 13.08 -1 0 1 2 3 4 Pm [dBr]